Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revisionPrevious revision
Next revision
Previous revision
brachial_plexus [2026/04/27 16:13] scottbrachial_plexus [2026/06/29 16:18] (current) scott
Line 1: Line 1:
 ======Brachial Plexus MRI====== ======Brachial Plexus MRI======
  
-=====Anatomy=====+=====Positioning=====
  
-The brachial plexus exam can be more difficult than a standard brain or spine exam, as there is more complex anatomy, different positioning requirements, and different scanning challenges A good sense of the anatomy is crucial to proper coverage and slice orientation.+Positioning for the brachial plexus exam is especially important. To ensure the nerves and forelimbs can be well assessedboth limbs should be positioned as __symmetrical__ as possible, and pulled __rostrally__ and well securedProper limb positioning will ensure that the peripheral brachial plexus nerves can be imaged closest to isocenter, compared slice-to-slice, and without excessive slice coverage. Typically dorsal recumbency is preferred, and any compatible coils that can be positioned over the elbows or sternum will help with SNR.
  
-The brachial plexuses are bundles of nerves that originate from about C4/5 to T2/3 and extends into the forelimbs on both sides. When there is an injury or lesion in the brachial plexus, a patient may present with muscle atrophy or forelimb lameness without an orthopedic cause. Below are MIPs of the brachial plexus nerves in 3 planes. Keep in mind that the nerves extend deeper into the forelimb than visualized on these sequences, so the required coverage will be larger.+=====Scan Coverage and Planning=====
  
-{{::nervestir_sag_mip.gif?}}  {{::nerve_stir_ax_mip.gif?}}  {{::nerve_stir_dor_mip.gif?}}+==== A note on Localizers==== 
 + 
 +When planning out your localizer images, be sure to use a LARGE FOV so that the forelimbs and shoulders are well demonstrated, positioning can be checked, and coil extents can be seenUse a LOT of slices to cover all the anatomy; you want to be able to find the shoulder joints, elbows,  and sternum on all three planes.
  
-=====Scan Coverage and Planning===== 
  
 ====Sagittal Plane==== ====Sagittal Plane====
 +
 +
 For brachial plexus scout images, add more slices on all planes to cover sternum to spine dorsally, shoulder to shoulder sagittal, and C3 to T3 axially. On the axial and dorsal scout imaging, plan the slices parallel to the center of the spinal cord. On the sagittal scout image, center the FOV on C6/7. For brachial plexus scout images, add more slices on all planes to cover sternum to spine dorsally, shoulder to shoulder sagittal, and C3 to T3 axially. On the axial and dorsal scout imaging, plan the slices parallel to the center of the spinal cord. On the sagittal scout image, center the FOV on C6/7.
 For each patient, the FOV should be re-sized to include at least C4/5 to include the T3/4. On the dorsal scout image, add enough slices to cover out to the humeral head on both sides unless specifically doing a unilateral study. **Be sure to use an ODD number of slices. This will ensure that the center slice is in true midline through the spinal cord.** For each patient, the FOV should be re-sized to include at least C4/5 to include the T3/4. On the dorsal scout image, add enough slices to cover out to the humeral head on both sides unless specifically doing a unilateral study. **Be sure to use an ODD number of slices. This will ensure that the center slice is in true midline through the spinal cord.**
Line 26: Line 29:
  
 ====Dorsal Plane==== ====Dorsal Plane====
-The dorsal plane is particularly useful when scanning for brachial plexus pathology, as it provides a good overview of both forelimbs symmetrically. As a first screening sequence, the dorsal should cover from the sternum to just past the vertebral bodies, with the FOV large enough to demonstrate both forelimbs. The __Brachial Plexus__ nerves exit ventrocaudally  from C4/5 to T1/2 and extend into the forelimbs and dorsal to the humeral head. Incidental findings are also frequently located on the dorsal plane (Right image, red arrow)+ 
 + 
 +The dorsal plane is particularly useful when scanning for brachial plexus pathology, as it provides a good overview of both forelimbs symmetrically. As a first screening sequence, the dorsal should cover from the sternum to just past the vertebral bodies, with the FOV large enough to demonstrate both forelimbs and shoulders. The __Brachial Plexus__ nerves exit ventrocaudally  from C4/5 to T1/2 and extend into the forelimbs and dorsal to the humeral head. Some plexus pathology may lead to changes in the signal intensity of muscles (Right image, red arrow)
  
 {{::bplexusdorplan.png?500|}}{{:dorincidental.png?500|}} {{::bplexusdorplan.png?500|}}{{:dorincidental.png?500|}}
Line 33: Line 38:
  
 ===Selecting Phase Direction=== ===Selecting Phase Direction===
-In the cervical spine, either A/P or S/I may be selected, but require slightly different acquisition strategies. 
-If choosing the phase direction S/I, motion artifact from respiration and flow the vessels in the cranial thorax will propagate S/I. Unlike awake human patients, there should be no motion artifact from swallowing. In the S/I direction there will be anatomy that extends beyond the FOV, and will require significant oversampling to prevent wrap artifact. This can add quite a bit of time, but will afford some extra SNR, so it may be possible to reduce time by reducing NEX/Averages. Note the flow artifact from the vessels (red arrow). If selecting the phase direction as A/P, it is possible to not only remove all the oversampling, but even to reduce the phase FOV to further reduce time. It is necessary with this method to prescribe a sat band over the cranial thorax to prevent flow artifact from propagating through the caudal cervical spine. It is important to note, this is not an appropriate method when brachial plexus pathology is suspected, as the sat band will obscure the nerve bundles.  
  
 +When imaging the brachial plexus, any phase direction may be used, but the A/P direction will allow for greater flexibility. A/P phase direction may allow for a rectangular FOV and reduced oversampling, both of which will save time that can be used for other motion reduction strategies. Unlike the cervical spine, saturation bands should not be used ventral to the spine to reduce flow and respiration artifact, as the nerves of interest run parallel to all the vessels and would be obscured. 
 +
 +===Reducing Motion and Flow===
 +
 +As the use of saturation bands would obscure important anatomy, motion reduction must be achieved with other methods. Here are a few parameter changes that can be made to reduce the effect of respiratory motion in the brachial plexus area:
 +
 +  * Increase NEX/Averages; 4 or more
 +  * Square matrix; ie 256x256 select a slightly lower resolution to save time and keep it square 
 +  * Utilize higher bandwidth
 +  * If applicable to your system, try PROPELLER/BLADE; pretty good for motion and also reduces flow artifact
 +
 +To reduce the effect of flow artifact:
 +
 +  * Use a slightly longer ETL/Turbo factor
 +  * Select a later TE (second echo for T1's)
 +  * If applicable to your system, 3D FSE's like CUBE/SPACE will naturally do an excellent job suppressing signal from vessels in all contrasts
 +
 +===Find Pathology===
 +
 +Locating pathology in brachial plexus scans can be difficult when a large lesion isn't present. There are a few things that can be done to help:
 +
 +  * Run a dorsal early in the exam, preferably a STIR
 +  * Check for symmetry; denervation changes can lead to T2 hyperintensity or muscle atrophy
 +  * Good fat saturation; use Dixon techniques whenever possible. If no Dixon is available, be sure to manually shim the area of interest
 +  * Run high resolution NON-fat saturated sequences; the nerves are fairly dark and will be more apparent when surrounded by bright fat
 +
 +===Fat Saturation===
 +
 +Fat saturation can be tricky in the cervical/plexus area due the uneven anatomy, presence of microchips, and large FOV's required. 
 +
 +{{::poorfatsat.png?400|}}
 +
 +  * Use Dixon techniques for fat saturation (Dixon, FLEX, IDEAL)
 +  * SPAIR/SPECIAL techniques may be a bit more homogenous if available
 +  * Manually shim to the area of interest
 +  * Position and scan close the isocenter
 +  * Use the smallest appropriate FOV